| Shopping Cart Empty Welcome, sign in Private person / Company / Distributor |
| Reference | Availability | Amount | Purchase | ||
|---|---|---|---|---|---|
|
207-CUHD1 |
|
6,495.00€
7,014.60€ (VAT Incl.)
|
||
|
207-CUHD1-SPO2 | With pulse oximetry probe |
|
7,495.00€
8,094.60€ (VAT Incl.)
|
207-CUHD1: With printer, and cable 3 leads ECG
207-CUHDIV1: With printer cable 3 leads ECG, SpO2, and pacemakers.
207-CUHDIV2: With printer cable, 12-Lead ECG, SpO2, and pacemakers.
207-CUHDIV3: With printer cable, 12-Lead ECG, SpO2, NIBP, and pacemakers.
Defibrillation biphasic truncated exponential waveform. e-cube
Monitoring NIBP, SpO2, ECG (12 Dervan.) Memory and trends.
External pacemaker.
DEA integrated.
Built-in printer.
Patient connection: Wheel or disposable defibrillation electrodes
Cable 3, 5, or 10 leads with ECG electrodes.
Deriv. monitored: I, II, III, aVR, aVF, aVL, V1, V2, V3, V4, V5, V6
Bandwidth: 0.3 ~ 40Hz (-3dB).
ECG size: 5, 10, 20 mm / mV - display GráficoECG.
Auto scaling of ECG wave.
Heart Rate: Digital 30 ~ 300 bpm. (± 3bpm).
Alarms: Configurable FC, minimum and maximum asystole, VF, VT.
Saturation: 70-100% (± 3 digits)
Pulse Ratio: 20 to 250 bpm. (± 3 digits)
Infusion: 0.2%. Configurable alarms.
Display Type: LCD high-resolution graphic
Screen Size: 7 "(152mm x 91mm)
Resolution max. : 800 x 480 pixels.
Sweep speed: 25mm/seg. nominal
Display Time: 3.2 sec. (ECG)
Information: Energy discharge, Synchronization, heart rate,
Palas Connectors / pads, Alarms. On / Off, Function and status AED, Defibrillator function test, correction of mistakes and errors. Curve Curve ECG and SpO2 plethysmograph (optional)
| Operational Mode: - Semi DEA AAMI DF-80, ERC 2005 - Manual. By PADS or disposable blades.Deriv selection: I, II, III, aVR, aVL, aVF, V. - Wheel / Pads. ECG ext. |
|---|
| Waveform: Biphasic truncated exponential e-cube |
| Power: Semi-Automatic: 150 J 50 ohm load. (Preset) |
| Variable energy. Selection of levels. |
| (150J, 150, 180J / 150J, 180J, 180J) |
| (50J, 50J, 100J / 50J, 100J, 100J) |
| Self-adjusting power according to patient impedance. |
| Charging time: less than 10 seconds. |
| Manual: Selecting energy variable. (20 levels) |
| 1-10j, 15j, 20J, 30J, 50J, 70J, 100J, 120J, 150J, 170j, 200j. |
| Internal paddles: 1-10j, 15j, 20J, 30J, 50J. |
| Patient Impedance: 25 Ohm to 175 Ohm, unbalanced. |
| Charge time: AC Adapter: less than 5 seconds to 200J. |
| Battery: less than 7 seconds to 200J |
| Sync Cardioversion: Energy Transfer for 60 ms. QRS peak. |
| Sensitivity and specificity 99.5% |
| Results according to AHA / IMT ECG Database. |
| Detection level> 0.10 mV ECG |
| Charging time: less than 10 seconds. (AED mode) |
| Pads: |
| Multi-functional electrodes. Disposable. |
| Adhesive pads for adults. |
| On / Off, Download (Shock) Buttons. Energy selector. Cardiosin-sync, bud analysis / Load Button Pause / downloads.Volume and screen menu controls. Print button. |
|---|
| Curve: monophasic truncated exponentialActivated by the user |
|---|
| Amplitude: 0 ~ 200 mA (± 5mA) |
| Pulse width: 20 ms (± 1.5%) |
| Heart Rate: 30 ~ 180 ppm (± 1.5%) |
| Refractory Period: 340 msec (30 to 80ppm); 240mseg (90 to 180ppm) |
Audible in Castilian, which guide the user through the ERC protocol 2005 in DEA. Example: Connect electrodes - Electrode Check - Do not touch the patient - Download - Check patient. etc.
Screen prompts are easy to interpret that guide the user through the proper protocol for action.
| ECG display, ability to see historical ECGEvents 6 hours recording ECG curves and 1 / 2 hour of recorded events or voices (depending on the SD card used) |
|---|
| Taxable LINEUP: Time, Date, FC, Downloads realized, unrealized downloads, download recommendations, or not, ECG Analysis, Test daily, weekly and monthly test and manuals, on-screen ECG gating. |
| Internal electronic test, analysis of the receiving system of curves and battery capacity.Check daily, weekly and monthly data stored. of environmental operating conditions and equipment. |
|---|
| Infrared port RS232 UART / IrDA.Transmitted data: ECG events, system software, test results, transmission between the unit and a PC. |
|---|
| Internal Rechargeable Battery. / 12V 4.2 Ah Ni / MH. 200 Downloads. (200j). Recharge time: Full charge in 4 hours.External Battery Pack (Pack of safety). Disposable. 14.8 V 3.1 Ah LiMnO2. 100 Downloads. (200j). |
|---|
| AC / DC Adapter Input :100-240V 50/60Hz 170 VA. Output: DC 18V, 5A |
| Galvanic Protection: BF TypeEnvironment: |
|---|
| - Operating: Temp. 0 º C to 40 º C |
| Humidity: 5% to 95% |
| - Storage and transportation: |
| Temperature. -20 º C to 60 º C |
Size: 318 x 208 x 355 mm
Weight: 4.7 kg with shovels.